*Excellent price performance ratio

Comprehensive application suite and powerful software included in standard configuration

*Patient friendly appearance  

Most open C-shaped magnet

*Minimal sitting requirements  

Less than 50 m² (538 sq.ft);

*Low operating Costs  

Permanent magnet - no helium

*Higher revenues  

Attractive to more patients and referring physicians

*Excellent Return On-Investment 

 Decreased costs-optimized profitability

*Efficient and Professional service team  

24 hours service on-line

 

Specifications of MY-D054(0.35T)  System

UUUUUUUUU1.0  Magnet:

Operating Field Strength         0.35 Tesla(3500 Gauss) 

Magnet Type                    Full open C-shaped, 2-colum

Magnetic material                Permanent Nd-Fe-B magnet

Homogeneity                    (400mm DSV) ≤ 2.0ppm (Vrms)

                                 (200mm DSV) ≤ ±1ppm (FWHH)

Shimming                       Passive & active shimming

Patient gap                      400mm(from cover to cover)

Net Weight                      17,500KGS

Dimension                      1970mm*1320mm*1820mm

UUUUUUUUU2.0  Gradient System:

Gradient strengh                max. 25mT/m (Gx/Gy/Gz)

Slew rate                       64mT/M/ms (Gx/Gy/Gz)

 

UUUUUUUUU3.0  RF System:

Spectrometer                   Digital (4 channels)

Transmitting coil                Flat planar coil

Receiving coils                  Phase array coil (Neck coil,  Head coil,  Large body coil,  Small body coil, Knee coil,)

Optional coils                   Wrist coil, Shoulder coil spine coil,  breast coil, ankle coil, etc.

Power of transmitter amplifier     6KW

 

UUUUUUUUU4.0  Computer System:

Operating system                Windows2000/NT/XP

CPU                             2.8GHz(Dual Core Processor)

Hard disk                        ≥250GB

RAM                             2048MB (2GB)

Display Device                   ≥22'' TFT

Network & laser printer interface   DICOM3.0

Software                          BASDA BTI-035 Software

 

5.0 Auto Pre- scan

 

6.0  Pulse Sequence:

Standard IR  

Spin Echo ( SE 2D/3D)

Multi-slice multi-echo (MSME)

Gradient Echo (GRE 2D/3D)

Steady state process gradient echo( SSPGRE)

Fast spin echo (FSE)

Single shot fast spin echo(SSFSE)

Multi shot fast spin echo (MSFSE)

Inversion recovery (IR)

Inversion recovery fast spin echo (IRFSE)

Short time inversion recovery (STIR)

Fluid attenuated inversion recovery ( FLAIR)

MRM ,MRU ,MRCP 

TOF 2D/3D MRA

Diffusion weighted imaging (DWI)

Echo planar imaging(EPI)

 

7.0 Image:

Acquisition matrix               64/128/256/512

Resolution                      1mm(head 24cm FOV 256X256)

                                1.5MM(body 30cm FOV 256X256)

                                0.5mm(head 24cm FOV 512X512)

                                0.75mm( body 30cm FOV 512X512)

Maximum display matrix         1024x1024

FOV                            20 ~ 400mm

Slice Orientation                Sagittal, coronal, transversal, any angle any oblique

Image Type                  T1 Weighted imaging , T2 weighted imaging ,T2* weighted imaging , proton density imaging;Water Suppressed Imange,Fat Suppressed Image, MRM, MRU,MRCP; Magnetic Resonance angiography (MRA), Diffusion Weighted Imaging (DWI)

  

8.0  Patient Table:

Max. Patient load about 240kg;

Available with laser light localizer for patient positioning

Longitudinal travel range: ≥1650mm

Intercommunication between patient and operator: available

 

9.0  Power Supply

3N~380/400V 50/60Hz 10KVA

                                

10.0  Typical Layout:

Magnet Room                          About 30 Square meters(5m×6m);

Equipment Room                       About 9 Square meters(3m×3m);

Control Room                          About 9 Square meters(3m×3m);

Total MRI-System area                  About 48 Square meters.

 

 

1. Magnet System

Feature Specification Analysis
Field Strength 0.35 Tesla (3500 Gauss) This is a lower magnetic field strength compared to higher-end models like 1.5T or 3T systems. While it may be suitable for basic imaging, it limits the resolution and speed of imaging, making it less ideal for detailed brain, musculoskeletal, or cardiac imaging.
Magnet Type Full open C-shaped, 2-column C-shaped design maximizes patient comfort by offering greater access and reducing the feeling of confinement. This can increase patient acceptance and may be beneficial for claustrophobic patients.
Magnetic Material Permanent Nd-Fe-B magnet Permanent magnets eliminate the need for costly helium and cooling systems, significantly reducing operational costs. However, the lower field strength may limit imaging capabilities.
Shimming Passive & Active Shimming Dual shimming (passive and active) helps maintain uniformity in the magnetic field, improving image quality and reducing distortion.
Homogeneity ≤ 2.0ppm (400mm DSV), ≤ ±1ppm (200mm DSV) Acceptable homogeneity for a 0.35T system, but lower than what you would expect from 1.5T or higher systems. This could affect the quality of certain high-resolution imaging.
Patient Gap 400mm The gap allows for comfortable patient positioning and accessibility, making it better for accommodating larger patients compared to standard narrow-bore designs.

2. Gradient System

Feature Specification Analysis
Gradient Strength 25mT/m (Gx/Gy/Gz) A lower gradient strength compared to higher-end MRI machines. While it is sufficient for basic imaging, it may struggle with more advanced techniques like diffusion tensor imaging (DTI) or functional MRI (fMRI).
Slew Rate 64mT/m/ms This is a decent slew rate for general imaging. However, faster imaging techniques such as echo planar imaging (EPI) or cardiac imaging may be limited in speed and accuracy.

3. RF System

Feature Specification Analysis
Spectrometer Digital (4 channels) Digital spectrometers offer better signal acquisition and faster processing. However, with 4 channels, this may limit the flexibility of more advanced multi-slice imaging or complex scans.
Transmitting Coil Flat planar coil Offers decent coverage for body imaging but may be limited for small structures like the brain or joints.
Receiving Coils Phase array coil (Neck, Head, Body, Knee, etc.) A variety of coils provide versatility for different imaging needs, improving patient comfort by targeting specific regions with minimal repositioning.
Power of Amplifier 6KW This is relatively modest power, but adequate for a 0.35T system. However, high-power sequences may have reduced efficiency.

4. Computer System

Feature Specification Analysis
Operating System Windows 2000/NT/XP Outdated OS, which may lead to security and compatibility issues. A more modern OS such as Windows 10 or embedded Linux would be ideal for a better user experience and system longevity.
CPU 2.8GHz (Dual Core) Decent performance for general use but may struggle with intensive image reconstruction.
Hard Disk ≥250GB Sufficient for storing moderate data, though an upgrade to larger capacity may be needed depending on the volume of imaging data.
RAM 2GB Minimal RAM — while functional, a higher RAM capacity would ensure faster processing and enhanced system performance, especially for larger datasets.
Display ≥22'' TFT Acceptable for basic image display but would benefit from higher resolution and larger screens for detailed interpretation of complex images.
Software BASDA BTI-035 Software Proprietary software should cover basic MRI needs but may lack advanced processing options available with higher-end systems.

5. Pulse Sequences

Feature Specification Analysis
Pulse Sequences Includes a wide variety (Spin Echo, Gradient Echo, FSE, Diffusion, MRA, DWI, etc.) Offers comprehensive sequence options for general clinical and research applications. While useful for basic scans, advanced sequences like fMRI or cardiac MRI may not perform as well with this system.

6. Image Quality

Feature Specification Analysis
Matrix 64/128/256/512 The available matrix sizes will allow reasonable resolution for general imaging. Higher matrix sizes are available but may strain the system’s performance, especially at 0.35T.
Resolution 1mm (head), 1.5mm (body) Adequate for basic clinical applications. High-resolution scans, especially for smaller structures, may not be as crisp as those from higher-field MRI systems (1.5T and above).
Maximum Display Matrix 1024x1024 A higher display matrix would ensure the best possible image clarity, but limitations in field strength and gradient performance may still lead to suboptimal results in some cases.
FOV (Field of View) 20~400mm Flexible, but limited compared to higher-field systems in terms of deeper tissue penetration and resolution.

7. Patient Table & Comfort

Feature Specification Analysis
Max Patient Load 240kg Suitable for most patients, including larger individuals.
Table Travel ≥1650mm Provides enough space for patient positioning and accommodates a wide variety of patient sizes.
Intercommunication Available Ensures effective communication between the operator and patient during the scan.

8. Power Supply & Layout

Feature Specification Analysis
Power Supply 3N~380/400V 50/60Hz 10KVA Requires a stable power source, but within typical MRI system power requirements.
Room Layout ~48m² Compact, requiring minimal space for MRI installation. This makes it suitable for smaller facilities or locations where space is limited.

9. Cost-Effectiveness & ROI

Feature Specification Analysis
Price-Performance Ratio Excellent With a low operating cost (no helium needed), this MRI system can be a cost-effective solution for clinics or smaller hospitals. It’s a solid option for facilities that need basic diagnostic capabilities but don’t have the budget for high-field MRI systems.
Patient Attraction Yes Its open design, lower price, and reduced operational costs make it an attractive option for a wide range of patients and referring physicians, potentially increasing patient volume and revenues.
Return on Investment (ROI) High Low maintenance and operational costs (no helium or liquid nitrogen) can significantly improve profitability. The system is ideal for high patient throughput with a smaller initial investment.

Overall Conclusion

The MY-D054 (0.35T) MRI system is an affordable, low-maintenance option that excels in cost-efficiency and patient comfort, making it ideal for smaller clinics or hospitals. However, its lower field strength (0.35T) means that it is not suitable for high-resolution, detailed imaging like brain, musculoskeletal, or cardiac scans. Its open design and low operational costs (no helium) make it appealing for patient comfort and ongoing cost savings.

For facilities focused on general imaging, patient accessibility, and cost reduction, this system provides a solid, cost-effective solution. However, those requiring advanced imaging capabilities or high-resolution scans may need to consider higher field strength systems (e.g., 1.5T or 3T).

View full details
Your cart
Variant Variant total Quantity Price Variant total
base
base
$330,000.00/ea
$0.00
$330,000.00/ea $0.00
custom
custom
$460,000.00/ea
$0.00
$460,000.00/ea $0.00

View cart
0

Total items

$0.00

Product subtotal

Taxes, discounts and shipping calculated at checkout.
View cart